Re: Maximum number for components for BOM

$
0
0

Kiran


I would question having too many components in a single BOM, the issue isn't just with the BOM creation but also with the explosion into an Production Order and the number of reservation lines created.


Although by adding lower level (LL) BOMs using Phantoms is possible, if this exceeds 1000 individual requirement lines in the reservation of the production order you will have issues.

I speak from experience here in a complex Automotive project where the BOM explosion was occurring via iPPE. In the end we had to look at the production process and decided that actually it should be split into more levels to reduce the BOM and resulting Reservations on orders.


Hope this helps

Cheers Andrew Bridge